﻿GET_GEVOMechL2_09_01_01_38 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:07,458
12. Prepare the conicals for transfer to the replacement alternator by cleaning and inspecting them.

2
00:00:07,458 --> 00:00:14,208
<b>Note:</b> The alternator conicals should be returned for complete inspection and overhaul every 9 years.

3
00:00:14,208 --> 00:00:23,958
<b>Caution:</b> Failing to fully unscrew the buffer stud before placing the alternator on the platform may allow the stud to press hard against the platform mounting pad.

4
00:00:23,958 --> 00:00:30,167
This will complicate setting conical clearance and recording accurate indicator readings during alignment.

5
00:00:30,167 --> 00:00:38,708
13. Install the conicals on the replacement alternator ensuring that the buffer stud is screwed completely counterclockwise.

6
00:00:38,708 --> 00:00:47,000
<b>Caution:</b> While cleaning the alternator plenum, take the necessary precautions to prevent debris from entering the alternator.

7
00:00:47,000 --> 00:00:57,667
14. Prepare the air duct adapter for transfer to the replacement alternator by removing any old sealant, dirt, grime, or rust.

8
00:00:57,667 --> 00:01:05,542
15. Install the adapter using grade 5 1/2 inch-13 x 1.75-inch bolts.

9
00:01:05,542 --> 00:01:10,250
<b>Note:</b> No sealant is required for a flat, clean surface.

10
00:01:10,250 --> 00:01:23,958
16. Torque the mounting bolts to 59 +3/-4 lb.-ft. (80 +4/-5 Nm).