﻿GET_GEVOMechL2_09_01_01_29 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:08,000
<b>Warning:</b> The corner air duct weighs approximately 260 lbs. (120 kg).

2
00:00:08,000 --> 00:00:12,500
Ensure the lifting device, cables, and straps are adequate.

3
00:00:12,500 --> 00:00:16,667
Failure to do so may result in personal injury or death.

4
00:00:16,667 --> 00:00:23,042
3. Remove the corner air duct from the B-side of the locomotive and save all hardware.

5
00:00:23,042 --> 00:00:28,375
a. Loosen the clamping bolt and the large washer under the air duct.

6
00:00:28,375 --> 00:00:36,125
b. Loosen the four bolts, the washers, and the lockwashers connecting the duct to the blower cab.

7
00:00:36,125 --> 00:00:42,417
c. Remove the mounting spring latch hardware at the top and bottom of the corner duct.

8
00:00:42,417 --> 00:00:47,750
d. Remove the clamping bolt and large washer under the air duct.

9
00:00:47,750 --> 00:00:55,417
e. Remove the remaining bolts, washers, and lockwashers connecting the duct to the blower cab.

10
00:00:55,417 --> 00:01:01,625
f. Properly attach the duct to the lifting device and remove it from the locomotive.

11
00:01:01,625 --> 00:01:06,542
4. Remove the hidden bolt located near the short hood end of the cab.

12
00:01:06,542 --> 00:01:15,042
<b>Warning:</b> The blower cab weighs approximately 4,000 lbs. (1,814 kg).

13
00:01:15,042 --> 00:01:19,583
Ensure the lifting device, cables, and straps are adequate.

14
00:01:19,583 --> 00:01:23,917
Failure to do so may result in personal injury or death.

15
00:01:23,917 --> 00:01:27,417
5. Remove the blower cab.