Typical steps to remove a brush holder and stud assembly are as follows:

2
00:00:04,833 --> 00:00:09,708
1. Remove all brushes from each of the assemblies.

3
00:00:09,708 --> 00:00:16,750
2. Disconnect the field cables from the bus rings at the 9 o' clock position of the brush holder stud.

4
00:00:16,750 --> 00:00:29,875
3. Slide a 0.06 inch (1.52 mm) thick sheet of heavy paper between the brush holders and the collector rings to protect the collector ring surfaces from damage.

5
00:00:29,875 --> 00:00:36,958
4. Loosen and remove four of the eight bolts securing the brush holder yoke to the mounting block.

6
00:00:36,958 --> 00:00:46,458
5. Insert a 0.5 - 13 alignment pin into two of the four exposed bolt holes and remove the four remaining bolts.

7
00:00:46,458 --> 00:00:55,250
6. Slide the yoke with all three brush holder and stud assemblies off the alignment pins and carefully transport it to a bench.