If a single brush holder or a brush holder stud needs to be replaced, remove the entire brush holder and stud assembly from the alternator, replace the faulty component, and return the whole assembly to the alternator.

2
00:00:12,875 --> 00:00:22,417
<b>Warning:</b> When using compressed air for cleaning purposes, an environment that is potentially hazardous to personnel in the immediate area is created.

3
00:00:22,417 --> 00:00:29,125
To prevent physical injury due to flying debris, observe all railroad and government safety regulations.

4
00:00:29,125 --> 00:00:32,667
Cleaning solvents may be toxic or flammable.

5
00:00:32,667 --> 00:00:37,708
They can cause serious or fatal injury if used without proper precautions.

6
00:00:37,708 --> 00:00:41,333
For safety: Do not inhale solvent fumes.

7
00:00:41,333 --> 00:00:45,083
Use solvents only in adequately ventilated areas.

8
00:00:45,083 --> 00:00:47,875
Avoid contact of solvent with skin.

9
00:00:47,875 --> 00:00:52,250
Observe caution statements issued by the manufacturer of the solvent.

10
00:00:52,250 --> 00:00:57,042
Typical steps to clean the brush holder and stud assembly are as follows:

11
00:00:57,042 --> 00:01:05,500
1. With the brush holder/collector ring cover removed, blow out the compartment with clean, dry compressed air.

12
00:01:05,500 --> 00:01:13,250
2. Wipe off the insulation between the collector rings and the collector ring studs with a clean, dry rag.

13
00:01:13,250 --> 00:01:21,833
3. Using an appropriate solvent, wipe away any residue from the brush holders with a clean, dry lint-free cloth.