﻿GET_GEVOMechL2_09_01_01_07 - ANIMATION Screen
1
00:00:00,000 --> 00:00:09,333
The TA’s field windings are excited by the Traction Alternator Field Controller (TAC) and produce a magnetic field of force.

2
00:00:09,333 --> 00:00:16,292
As the engine’s mechanical energy turns the rotor, electrical energy is induced into the TA stator windings.

3
00:00:16,292 --> 00:00:25,583
These windings produce a 3-phase AC voltage output that is directly proportional to the field excitation current for a given engine RPM.

4
00:00:25,583 --> 00:00:32,250
The induced 3-phase AC voltage is then fed to rectifier modules and converted to DC power.

5
00:00:32,250 --> 00:00:40,375
On an ES44DC locomotive, this DC power is directly distributed to the six DC traction motors.

6
00:00:40,375 --> 00:00:53,042
On an ES44AC locomotive, the rectified DC power is inverted back into 3-phase AC power by the traction inverters and then distributed to the six AC traction motors.

7
00:00:53,042 --> 00:00:58,958
The traction motors convert the electrical power back into mechanical power to pull a train.