﻿GET_GEVOMechL2_08_01_01_75 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:05,458
Typical steps to install the U-tube, wheels, and axle are as follows:

2
00:00:05,458 --> 00:00:17,625
1. Clean the traction motor frame and U-tube mounting surfaces with a rag dipped in an approved solvent, then wipe the mounting surfaces with a clean rag to remove any excess solvent.

3
00:00:17,625 --> 00:00:31,333
2. Apply a gasket (Part Number 41A239176P317) to the commutator end of the traction motor frame where the U-tube mounts to the frame and trim the gasket to fit.

4
00:00:31,333 --> 00:00:44,833
3. Apply another gasket (Part Number 41A239176P317) to the pinion end of the traction motor frame where the U-tube mounts to the frame and trim the gasket to fit.