﻿1
00:00:00,000 --> 00:00:06,667
10. If no bearing defects are found, flush the bearings with HD 57 oil. 

2
00:00:06,667 --> 00:00:12,250
11. Inspect the oil metering hole and trough screen for debris. 

3
00:00:12,250 --> 00:00:15,542
Flush the trough until no debris washes out. 

4
00:00:15,542 --> 00:00:22,417
12. Clean the bearing cap, apply a new gasket, and return the bearing cap to the traction motor. 

5
00:00:22,417 --> 00:00:27,750
<b>Note:</b> Ensure that grade 8 bolts are used and are properly torqued.