﻿GET_GEVOMechL2_06_01_01_18 - ANIMATION Screen
1
00:00:00,000 --> 00:00:09,792
For end traction motor locations (TM1, TM3, TM4, and TM6), no lateral gap measurement should exceed 3/8 inch.

2
00:00:09,792 --> 00:00:18,000
For center traction motor locations (TM2 and TM5), no lateral gap measurement should exceed 7/8 inch.

3
00:00:18,000 --> 00:00:24,667
If the pedestal liners are damaged or if clearances exceed the maximum limits, replace them as follows:

4
00:00:24,667 --> 00:00:30,458
1. Remove the bearing housing retainer and then remove the damaged or worn liner.

5
00:00:30,458 --> 00:00:38,417
2. Install the new pedestal liner and retainer, then torque the retainer bolts to the proper value.