﻿GET_GEVOMechL2_05_01_01_72 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:03,833
3. Disconnect all fan motor leads.

2
00:00:03,833 --> 00:00:12,042
4. Remove and save all bolts and washers that secure the air-to-air fan assembly to the air-based intercooler frame.

3
00:00:12,042 --> 00:00:15,292
<b>Note: </b>Save all hardware for reuse.

4
00:00:15,292 --> 00:00:22,833
<b>Warning: </b>The air-to-air fan assembly weighs approximately 300 lbs. (136 kg).

5
00:00:22,833 --> 00:00:25,750
Ensure the lifting device is adequate.

6
00:00:25,750 --> 00:00:30,292
Failure to do so may result in personal injury or death.

7
00:00:30,292 --> 00:00:36,000
5. Attach a crane or lifting device to the lifting hooks on the fan assembly.

8
00:00:36,000 --> 00:00:41,083
6. Remove the air-to-air fan assembly from the locomotive.