﻿GET_GEVOMechL2_05_01_01_62 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:09,625
<b>Note: </b>The air lines should be labeled before being removed from the shutter cylinders to ensure they will not be reversed when re-installing the shutters.

2
00:00:09,625 --> 00:00:20,417
14. For a top-mounted shutter assembly, remove the shutter actuator cover to allow access to the air lines, then disconnect the air lines on the shutter cylinders.

3
00:00:20,417 --> 00:00:27,833
15. For side-mounted shutter assemblies, disconnect the air lines from the two shutter cylinders.

4
00:00:27,833 --> 00:00:34,500
<b>Note: </b>Not all Evolution Series locomotives are equipped with an air-to-air shutter assembly.

5
00:00:34,500 --> 00:00:39,542
Some locomotives have a covering grate in place of the air-to-air shutter assembly.

6
00:00:39,542 --> 00:00:50,542
16. Unbolt the four vertical mounting bolts on the radiator cab support wings on each side of the locomotive by accessing the bolts through the side screen openings.

7
00:00:50,542 --> 00:01:01,167
<b>Warning: </b>The air-based intercooler weighs approximately 3375 lbs. (1530 kg).

8
00:01:01,167 --> 00:01:03,875
Ensure the lifting device is adequate.

9
00:01:03,875 --> 00:01:07,792
Failure to do so may result in personal injury or death.

10
00:01:07,792 --> 00:01:15,625
17. Attach a four-hook lifting device at the lifting points and lift the air-based intercooler package from the locomotive.

11
00:01:15,625 --> 00:01:22,792
18. Align and place the air-based intercooler package in the support stand on the shop floor.