﻿GET_GEVOMechL2_05_01_01_32 - ANIMATION Screen
1
00:00:00,000 --> 00:00:09,083
As part of a two-stage manifold air-cooling process, the Water-Based Intercooler (WBIC) provides the first stage of this cooling.

2
00:00:09,083 --> 00:00:14,333
The WBIC cools the air discharged from the turbocharger.

3
00:00:14,333 --> 00:00:22,083
At Notch 8 engine speed, the outlet air temperature from the WBIC is typically around 200&#xb0;F.

4
00:00:22,083 --> 00:00:29,042
<b>Note:</b> Engine load, altitude, and ambient air temperature can significantly affect this value.

5
00:00:29,042 --> 00:00:33,375
The WBIC consists of a core and an outer shell.

6
00:00:33,375 --> 00:00:36,875
The core is a mechanically bonded tube and fin design.

7
00:00:36,875 --> 00:00:42,750
The cooling water flows inside the tubes and makes two passes through the shell before exiting.

8
00:00:42,750 --> 00:00:47,875
The turbocharger discharge air flows over the tubes and fins in one pass.

9
00:00:47,875 --> 00:00:54,917
Perform the removal and installation steps as discussed in the Split Cooling Water System module of this course.