﻿GET_GEVOMechL2_03_01_01_65 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:07,125
6. Remove the Victaulic couplings that connect the various water flowpaths to the univalve.

2
00:00:07,125 --> 00:00:16,875
<b>Note:</b> For additional information on disassembly and removal of the Victaulic couplings, refer to the Victaulic Coupling Removal section of this module.

3
00:00:16,875 --> 00:00:25,542
7. Remove and save the four bolts, washers, and lockwashers that secure the univalve mounting clamps.

4
00:00:25,542 --> 00:00:31,125
8. Remove and save the two univalve mounting clamps and cushion inserts.

5
00:00:31,125 --> 00:00:39,000
<b>Warning:</b> The univalve assembly weighs approximately 250 lbs. (113 kg).

6
00:00:39,000 --> 00:00:42,125
Ensure the lifting device is adequate.

7
00:00:42,125 --> 00:00:46,250
Failure to do so may result in personal injury or death.

8
00:00:46,250 --> 00:00:51,500
9. Remove the univalve assembly with an appropriate lifting device.