﻿GET_GEVOMechL2_03_01_01_63 - ANIMATION Screen
1
00:00:00,000 --> 00:00:12,000
In Mode 1, the univalve mode indicator should be in the 12 o'clock position, and WFV1, WFV2, and WFV3 should be energized.

2
00:00:12,000 --> 00:00:19,625
In Mode 2, the univalve mode indicator should be in the 2 o'clock position, and WFV2 should be energized.

3
00:00:19,625 --> 00:00:27,833
In Mode 3, the univalve mode indicator should be in the 4 o'clock position, and all WFVs should be de-energized.

4
00:00:27,833 --> 00:00:33,625
In addition, the solenoid on each univalve control magnet valve can be manually overridden.

5
00:00:33,625 --> 00:00:38,417
The magnet valve picks up when the manual override plunger is pressed down.

6
00:00:38,417 --> 00:00:45,292
The illustration indicates which magnet valve needs to be on or off to switch the univalve to a particular mode.