00:00:00,000 --> 00:00:04,625
To drain the cooling water system, first, shut down the engine.

2
00:00:04,625 --> 00:00:09,583
Then, open the manual water drain valve located by the water pump.

3
00:00:09,583 --> 00:00:20,333
<b>Warning:</b> To prevent personal injury and potential equipment damage, ensure that the engine cannot be started before removing, installing, or adjusting any components.

4
00:00:20,333 --> 00:00:24,958
Open the Battery Switch (BS) to prevent starting attempts.

5
00:00:24,958 --> 00:00:34,167
Also, place the Fuel Pump Circuit Breaker (FPB) and the Local Control Circuit Breaker (LCCB) in the OFF position.

6
00:00:34,167 --> 00:00:38,750
Apply a warning tag to the Engine Control (EC) switch.

7
00:00:38,750 --> 00:00:45,583
It is recommended to collect water samples for analysis at a minimum frequency of seven to ten days.

8
00:00:45,583 --> 00:00:52,958
Have the sample analyzed by a qualified laboratory, and then take the appropriate action based on the analysis.

9
00:00:52,958 --> 00:00:58,583
Before taking a water sample, write all pertinent information on the sampling bottle.

10
00:00:58,583 --> 00:01:04,208
Print the information clearly and keep the label clean so that a lab technician can read it.

11
00:01:04,208 --> 00:01:10,458
Collect the water sample by using one of the water-sampling valves on the water sight glass housing.

12
00:01:10,458 --> 00:01:15,375
Fill the water sample bottle 2/3 to 3/4 full.