﻿GET_GEVOMechL2_03_01_01_34 - ANIMATION Screen
1
00:00:00,000 --> 00:00:07,292
If the maximum allowable ΔT limit is exceeded, the engine horsepower will be derated as displayed in the table.

2
00:00:07,292 --> 00:00:14,750
If the ΔT is not within the limit five minutes after the initial violation, the engine goes to IDLE.

3
00:00:14,750 --> 00:00:21,417
If the ΔT is not within the limit 10 minutes after the initial violation, the engine is shut down.

4
00:00:21,417 --> 00:00:28,833
If at any time the ΔT returns to an allowable limit, the engine horsepower is restored to 100%.