﻿GET_GEVOMechL2_03_01_01_31 - ANIMATION Screen
1
00:00:00,000 --> 00:00:10,833
When the engine inlet water temperature (as read by the EWIT sensor) is hot, the available horsepower from the engine is reduced to protect the engine from damage.

2
00:00:10,833 --> 00:00:19,958
At the same time, the engine speed increases to 1050 RPM to provide the highest radiator fan speed and maximum cooling.

3
00:00:19,958 --> 00:00:40,583
When the engine inlet water temperature exceeds 230°F for two seconds, the engine speed increases to 1050 RPM (an EMS_HOT_ENGINE_1050_INC is logged) and the available horsepower is modulated to hold the engine inlet water temperature at 230°F.

4
00:00:40,583 --> 00:00:49,083
If the available horsepower has been reduced to 80% or less for one minute, an EMS_HOT_WATER_DERATION_INC is logged.

5
00:00:49,083 --> 00:01:02,750
If the attempt to control the water temperature fails, and the available horsepower has been reduced to 0% for five minutes, the engine shuts down and an EMS_HOT_WATER_SHUTDOWN_INC will be logged.