Although the radiator is warmer because of the energy transfer from the water, the temperature difference between the water and the metal is still large enough that the rate of heat transfer from the water to the metal may cause the water to freeze while the radiator is draining.

2
00:00:15,333 --> 00:00:24,625
When the computer software adjusts the cooling process to account for ambient temperature and horsepower, the following flow control strategies are used:

3
00:00:24,625 --> 00:00:28,667
Low Ambient Flow Control Using Water Temperature Set Points

4
00:00:28,667 --> 00:00:32,625
High Ambient Flow Control Using Water Temperature Set Points

5
00:00:32,625 --> 00:00:37,167
Flow Control Using Lube Oil Temperature Set Points