﻿GET_GEVOMechL2_03_01_01_35 - ANIMATION Screen
1
00:00:00,000 --> 00:00:05,917
The split cooling water system maintains the cooling water within a certain range of temperatures.

2
00:00:05,917 --> 00:00:20,958
To accomplish this, the water temperature (as read by the EWIT sensor) and lube oil temperature (as read by the ELIT sensor) are monitored, and then the water flow path or the radiator fan speed is changed accordingly.

3
00:00:20,958 --> 00:00:31,208
Changing the flow path for the cooling water is accomplished with the univalve and can be thought of as making a course adjustment (or Mode selection) to the cooling process.

4
00:00:31,208 --> 00:00:36,417
Changing the radiator fan speed is done within a course adjustment, or Mode.

5
00:00:36,417 --> 00:00:40,875
This can be thought of as making a fine adjustment to the cooling process.