﻿GET_GEVOMechL2_03_01_01_32 - ANIMATION Screen
1
00:00:00,000 --> 00:00:06,833
The first path is through the oil cooler and the water-based intercooler, and then back to the water storage tank.

2
00:00:06,833 --> 00:00:12,542
This path either warms or cools the lubricating oil and intake manifold air.

3
00:00:12,542 --> 00:00:19,083
The second path is through the radiator and its sub-coolers, and then back to the water storage tank.

4
00:00:19,083 --> 00:00:24,458
A motor-driven radiator fan pushes air through the radiator to cool the engine water.

5
00:00:24,458 --> 00:00:32,667
Varying the fan motor speed from off to 1/4, 1/2, or full engine speed controls the amount of cooling that occurs.

6
00:00:32,667 --> 00:00:38,958
For more information on manifold air temperature control, refer to the Combustion Air System module.