﻿GET_GEVOMechL2_03_01_01_115 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:05,292
Typical steps to replace the automatic water drain valve assembly are as follows:

2
00:00:05,292 --> 00:00:09,417
1. Drain the locomotive cooling water system.

3
00:00:09,417 --> 00:00:19,958
2. Remove the two screws, lockwashers, and nuts from each connecting flange and remove the entire automatic water drain valve body from the piping.

4
00:00:19,958 --> 00:00:25,167
3. Discard the O-ring seals and replace with new O-rings.

5
00:00:25,167 --> 00:00:34,125
<b>Note:</b> When reassembling, apply a small amount of grease (Dow Corning 55M or equivalent) to the O-ring seals.

6
00:00:34,125 --> 00:00:43,708
4. Install the replacement water drain valve assembly to the connecting flanges by securing with screws, lockwashers, and nuts.