﻿GET_GEVOMechL2_03_01_01_114 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:06,208
Typical steps to install the actuating portion of the automatic water drain valve are as follows:

2
00:00:06,208 --> 00:00:16,833
<b>Caution:</b> Failure to install the hex body and cartridge properly will cause insufficient opening of the internal check valve, resulting in little or no drainage from the valve.

3
00:00:16,833 --> 00:00:23,000
1. Chase the internal threads of the pipe tee to remove any rust or debris.

4
00:00:23,000 --> 00:00:32,958
2. Using an approved low strength thread sealant (Loctite<sup>®</sup> 567), screw the new hex body and cartridge into the leg of the pipe tee.

5
00:00:32,958 --> 00:00:41,417
3. Tighten the hex body into the pipe tee to a torque value of 80 lb.-ft. (108 Nm).