﻿GET_GEVOMechL2_03_01_01_86 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:08,542
<b>Note:</b> If using a crane and lifting fixture, switch the crane hook from the loaded lifting location to the empty lifting location.

2
00:00:08,542 --> 00:00:19,375
4. Carefully remove the forks from the radiator fan motor box sections, preventing the radiator fan and motor or radiator fan support from shifting position.

3
00:00:19,375 --> 00:00:33,417
5. Install the previously removed and saved four long mounting bolts with a lockwasher under each head through the radiator fan motor box sections and the radiator fan support into the radiator cab structure.

4
00:00:33,417 --> 00:00:45,292
6. Torque the four bolts to 440-490 lb.-ft. (597-665 Nm).