﻿GET_GEVOMechL2_03_01_01_104 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:04,583
Typical steps to remove the radiator fan are as follows:

2
00:00:04,583 --> 00:00:15,458
<b>Warning:</b> To prevent personal injury and potential equipment damage, ensure that the engine cannot be started before removing, installing, or adjusting any components.

3
00:00:15,458 --> 00:00:18,583
Open the BS to prevent starting attempts.

4
00:00:18,583 --> 00:00:24,000
Also, place the FPB and the LCCB in the OFF position.

5
00:00:24,000 --> 00:00:27,125
Apply a warning tag to the EC switch.

6
00:00:27,125 --> 00:00:34,250
<b>Warning:</b> If the locomotive is equipped with AESS, the diesel engine may start without operator action.

7
00:00:34,250 --> 00:00:38,292
Exercise caution when working around the radiator cab.

8
00:00:38,292 --> 00:00:43,833
Ensure that AESS is disabled before performing any maintenance on the locomotive.

9
00:00:43,833 --> 00:00:48,875
Failure to do so may result in death or serious personal injury.

10
00:00:48,875 --> 00:00:56,542
1. Remove and save the eight bolts that hold the large screen on the left side of the radiator cab.

11
00:00:56,542 --> 00:01:02,458
2. Carefully, remove the large cab screen assembly and set it aside.

12
00:01:02,458 --> 00:01:10,833
3. Disconnect the three lead wires from the terminal block located on the underside of the radiator fan motor.

13
00:01:10,833 --> 00:01:21,375
4. Note carefully the identification of the lead on each terminal for subsequent reassembly, then install the hardware back on the terminal block studs.