﻿GET_GEVOMechL2_02_01_01_97 - ANIMATION Screen
1
00:00:00,000 --> 00:00:06,375
Maintenance for the coalescer is condition-based except for annual eductor tube cleaning. 

2
00:00:06,375 --> 00:00:13,250
If a problem does occur and the coalescer system is suspected, check these five basic areas: 

3
00:00:13,250 --> 00:00:19,458
Hoses: Hole in the hose, crushed or damaged hose, leaky connection

4
00:00:19,458 --> 00:00:24,083
Coalescer canister: Damaged or hole in the canister

5
00:00:24,083 --> 00:00:30,500
O-ring seal: Missing or damaged O-ring seal between coalescer canister halves

6
00:00:30,500 --> 00:00:34,667
Filter element: Dirty or clogged filter element

7
00:00:34,667 --> 00:00:38,583
Eductor tube: Carbon buildup in the tube