﻿GET_GEVOMechL2_02_01_01_95 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:10,583
9. With the engine at IDLE, check and fill the crankcase lubricating oil level as discussed in the Lubricating Oil Level Check and Fill section of this module. 

2
00:00:10,583 --> 00:00:22,708
10. With the engine at IDLE, visually inspect the engine, lubricating oil pump, oil cooler, oil filter, pre-lube pump, and all system piping for oil leaks. 

3
00:00:22,708 --> 00:00:30,333
11. Torque the Victaulic coupling bolts to the recommended specification for the particular application. 

4
00:00:30,333 --> 00:00:38,583
12. Ensure that the Victaulic couplings are pointed out, mounted horizontally with respect to the split line of the coupling. 

5
00:00:38,583 --> 00:00:44,833
<b>Note: </b>Some dripping of lubricant from pipe joints may occur as the engine and piping warms up. 

6
00:00:44,833 --> 00:00:50,083
This should not cause a concern unless you see evidence of joint leakage.