3. Disconnect the oil filter housing from the oil cooler as follows:

2
00:00:05,708 --> 00:00:14,250
<b>Note: </b>As oil pipes are disconnected from the lubricating oil cooler, blanking plates must be placed on the oil cooler openings.

3
00:00:14,250 --> 00:00:25,250
The oil cooler, oil filter housing, and pipe openings should be plugged or blocked to prevent oil from spilling out of the oil cooler or draining from the disconnected pipes.

4
00:00:25,250 --> 00:00:40,250
a. Disconnect the pipe sections connecting the oil cooler to the oil filter housing, bolt a blanking plate to the oil cooler outlet flange opening, plug or block all pipe openings, and save all removed hardware.

5
00:00:40,250 --> 00:00:50,208
b. Disconnect the pipes that are on the back of the oil filter housing, plug or block all pipe openings, and save all removed hardware.

6
00:00:50,208 --> 00:01:02,542
c. Disconnect the oil filter housing drain back valve drain flange and drain piping assembly, plug or block all flange openings, and save all removed hardware.