﻿GET_GEVOMechL2_02_01_01_68 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:05,708
4. Disconnect the oil cooler from the oil filter housing as follows: 

2
00:00:05,708 --> 00:00:14,167
<b>Note: </b>As oil pipes are disconnected from the lubricating oil cooler, blanking plates must be placed on the oil cooler openings. 

3
00:00:14,167 --> 00:00:23,625
The oil and water pipe openings should be plugged or blocked to prevent oil and water from spilling out of the cooler or draining from the disconnected pipes. 

4
00:00:23,625 --> 00:00:33,250
<b>Note: </b>The cooler holds approximately 11 gallons of oil, which cannot be drained until the oil cooler is removed and tipped at an angle. 

5
00:00:33,250 --> 00:00:48,208
a. Disconnect the pipe sections connecting the oil cooler to the oil filter housing, bolt a blanking plate to the oil cooler outlet flange opening, plug or block all pipe openings, and save all removed hardware. 

6
00:00:48,208 --> 00:01:02,833
b. To aid in oil cooler removal, disconnect the pipe sections that are on the back of the oil filter housing and crossing over the oil cooler, plug or block all pipe openings, and save all removed hardware. 

7
00:01:02,833 --> 00:01:17,292
c. To allow oil cooler removal, disconnect the oil filter housing drain back valve drain flange and drain piping assembly, plug or block all flange and pipe openings, and save all removed hardware.