﻿GET_GEVOMechL2_02_01_01_64 - ANIMATION Screen
1
00:00:00,000 --> 00:00:03,958
Visually inspect the oil pump for any leaks or cracks.

2
00:00:03,958 --> 00:00:10,208
 Closely check around the joint areas, such as the oil pump suction and discharge lines.

3
00:00:10,208 --> 00:00:15,417
 If any leaks are found in the piping joints, try tightening the joint first.

4
00:00:15,417 --> 00:00:20,208
 If this fails to stop a leak, remove the pump and replace the gaskets.

5
00:00:20,208 --> 00:00:25,125
 Listen for any unusual noises coming from the pump, and correct as needed.

6
00:00:25,125 --> 00:00:36,250
 For removal and installation of the lubricating oil pump, refer to the Lubricating Oil Pump Removal and Installation module of the GEVO Diesel Engine Advanced course for instructions.

7
00:00:36,250 --> 00:00:44,208
 Inspection and maintenance related activities for the other lubricating oil system key components are discussed in the following sections.