The inspection and running maintenance requirements for the lubricating oil system include both visual inspections and periodic maintenance for the following key components: 

2
00:00:10,417 --> 00:00:12,333
Lubricating Oil Pump

3
00:00:12,333 --> 00:00:14,333
Lubricating Oil Cooler

4
00:00:14,333 --> 00:00:16,667
Lubricating Oil Filter

5
00:00:16,667 --> 00:00:19,333
Pre-Lube Pump and Motor Assembly

6
00:00:19,333 --> 00:00:21,083
Victaulic Couplings

7
00:00:21,083 --> 00:00:22,667
Coalescer

8
00:00:22,667 --> 00:00:27,583
The lubricating oil pump circulates oil through the lubricating oil system. 

9
00:00:27,583 --> 00:00:32,208
The pump has a positive displacement design and an internal relief valve. 

10
00:00:32,208 --> 00:00:41,000
The oil pump is mounted on the engine's IFE cover and is gear driven from the engine crankshaft by means of an auxiliary drive gear. 

11
00:00:41,000 --> 00:00:50,250
The oil pump moves approximately 475 GPM of oil at Notch 8 engine speed and normal operating temperature. 

12
00:00:50,250 --> 00:00:58,875
An internal relief valve protects the pump from overload conditions, such as those caused by a clogged filter assembly or oil cooler. 

13
00:00:58,875 --> 00:01:03,208
The relief valve fully opens at 150 psi.