﻿GET_GEVOMechL2_02_01_01_59 - ANIMATION Screen
1
00:00:00,000 --> 00:00:07,125
Engineering recommends that oil samples be collected for analysis at a minimum frequency of 7 to 10 days.

2
00:00:07,125 --> 00:00:16,500
Take a sample from the lubricating oil vent and sampling valve or quick-disconnect on the inlet pipe to the oil filter housing or on the filter housing door.

3
00:00:16,500 --> 00:00:23,250
Have the sample analyzed by a qualified laboratory, and then take the appropriate action based on the analysis.

4
00:00:23,250 --> 00:00:38,792
For example, it may become necessary to find and correct the cause of oil dilution by diesel fuel or water; or to find and correct the cause of an increase of metals in the oil, such as copper, iron, chromium, and aluminum.