To provide additional engine protection, the engine can only run with the ELIT value above 185°F for limited periods and conditions. 

2
00:00:10,417 --> 00:00:19,500
These conditions include periods of transients, when in a tunnel, during hot days, and when the cooling water system has malfunctioned. 

3
00:00:19,500 --> 00:00:24,625
The EMS software uses the hot oil set point value to help govern this function. 

4
00:00:24,625 --> 00:00:32,958
If the locomotive runs for a week with an unhealthy cooling system, the hot oil set point value decreases by 10 degrees. 

5
00:00:32,958 --> 00:00:41,792
When this occurs, the smart display indicates an incident, and the hot oil set point remains at 185°F. 

6
00:00:41,792 --> 00:00:47,250
To reset this incident requires Level 3 access of the smart display. 

7
00:00:47,250 --> 00:00:51,458
The following conditions determine the health of the cooling system: 

8
00:00:51,458 --> 00:00:54,833
The locomotive is running at Notch 8, and

9
00:00:54,833 --> 00:00:59,250
The ambient temperature &lt; 90°F, and

10
00:00:59,250 --> 00:01:05,458
The average ELIT &gt; 185°F, and

11
00:01:05,458 --> 00:01:12,958
All of the above are true for 24 hours (the duty cycle of Notch 8 is 24 hours of operation in a week).