﻿GET_GEVOMechL2_02_01_01_30 - ANIMATION Screen
1
00:00:00,000 --> 00:00:10,458
If the engine lubricating oil inlet temperature is greater than 150°F, the pre-lube pump operates for two minutes, and then the diesel engine cranks.

2
00:00:10,458 --> 00:00:19,625
 If the oil inlet temperature is less than 150°F, the pre-lube pump operates for four minutes before the diesel engine cranks.

3
00:00:19,625 --> 00:00:31,500
 During the four-minute pre-lube cycle, if ELIP pressure does not rise 0.5-psi or greater for 10 continuous seconds, a non-restrictive incident is logged.

4
00:00:31,500 --> 00:00:36,333
 If the engine does not start, a second pre-lube cycle is initiated.

5
00:00:36,333 --> 00:00:44,750
 If the oil pressure fails to build again, a restrictive Automatic Engine Start/Stop (AESS) incident is logged.

6
00:00:44,750 --> 00:00:50,625
 The pre-lube pump is driven directly by a coupled compound-wound DC motor.

7
00:00:50,625 --> 00:00:56,542
 The input power flows from the locomotive battery through a contactor to the motor.