﻿GET_GEVOMechL2_02_01_01_101 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:06,667
6. When installing the upper coalescer hose, perform the following additional steps: 

2
00:00:06,667 --> 00:00:11,417
a. Attach the P-clamps to the upper coalescer hose. 

3
00:00:11,417 --> 00:00:17,667
Ensure that the P-clamp bolts are torqued so that the hose does not get twisted or damaged. 

4
00:00:17,667 --> 00:00:25,000
b. Connect the steel braided boost hose to the eductor and the tee fitting in the turbocharger casing. 

5
00:00:25,000 --> 00:00:29,708
c. Install the tie-wraps and spacer blocks. 

6
00:00:29,708 --> 00:00:35,500
<b>Note: </b>The spacer blocks should be used at the lowest tie-wrap location. 

7
00:00:35,500 --> 00:00:48,500
d. Ensure that the spacer block located opposite to the steel braided boost hose on the lowest tie-wrap is in contact with the turbo case to prevent premature coalescer hose failure. 

8
00:00:48,500 --> 00:00:58,125
<b>Caution: </b>Missing P-clamps or failure to install the spacer blocks at the lowest tie-wrap location may cause premature equipment failure. 

9
00:00:58,125 --> 00:01:18,000
<b>Note: </b>When installing the upper hose, upon completion of the installation of the end clamps, re-fasten the P-clamp around the center of the hose to the turbo flange with the 3/4-inch (19-mm) bolt and torque the bolt to 140 lb.-ft. (190 Nm).