﻿GET_GEVOMechL2_11_01_01_57 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:06,250
Typical steps to install the coalescer element in the Salem 824 filter are as follows:

2
00:00:06,250 --> 00:00:14,375
1. Carefully insert the new coalescer element into the filter body followed by the coalescer retainer and wing nut.

3
00:00:14,375 --> 00:00:25,292
<b>Note:</b> Ensure that the guide pin on the coalescer retainer is inserted properly into the guide pin receptacle on the coalescer deflector, then tighten the wing nut securely.

4
00:00:25,292 --> 00:00:31,333
2. Inspect the sump bowl gasket for damage and replace as required.

5
00:00:31,333 --> 00:00:40,625
3. Wipe any debris from the sump bowl before reassembling the repaired drain valve to the sump bowl and then the sump bowl to the filter body.

6
00:00:40,625 --> 00:00:45,792
4. Reconnect the actuating air line to the drain valve.