﻿GET_GEVOMechL2_11_01_01_56 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:06,250
Typical steps to remove the coalescer element in the Salem 824 filter are as follows:

2
00:00:06,250 --> 00:00:11,250
1. Disconnect the actuating air line to the drain valve.

3
00:00:11,250 --> 00:00:15,583
2. Remove the eight hex nuts and lockwashers.

4
00:00:15,583 --> 00:00:22,000
3. Use the screwdriver slots to loosen and remove the sump bowl and drain valve.

5
00:00:22,000 --> 00:00:27,083
4. Remove the wing nut and seat washer from the tube assembly.

6
00:00:27,083 --> 00:00:34,125
5. Remove the coalescer retainer, then remove the coalescer element and discard.