﻿GET_GEVOMechL2_11_01_01_55 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:06,958
Typical steps to install the filter element in the Salem 975 filter are as follows:

2
00:00:06,958 --> 00:00:12,625
1. Clean the inside of the filter body and bottom cap with solvent.

3
00:00:12,625 --> 00:00:22,125
<b>Note:</b> When installing a filter element, lubricate the sealing surface at both ends of the element with Dow Corning M55 or equivalent.

4
00:00:22,125 --> 00:00:31,792
2. Carefully install the filter element on the filter retaining device in the filter body assembly followed by the filter retainer and wing nut.

5
00:00:31,792 --> 00:00:37,167
3. Install a gasket on the bottom cap and assemble it to the filter body.

6
00:00:37,167 --> 00:00:41,667
<b>Note: </b>Assemble the gasket with the sealing bead on top.

7
00:00:41,667 --> 00:00:49,375
4. Secure the bottom cap to the filter body assembly using six lockwashers and hex nuts.