﻿GET_GEVOMechL2_11_01_01_42 - STEP-BY-STEP Cont Screen
1
00:00:00,000 --> 00:00:06,458
7. Disconnect the air compressor discharge piping at the aftercooler outlet flange.

2
00:00:06,458 --> 00:00:13,250
8. Exhaust the unloader piping, and remove the unloader hose from the air compressor.

3
00:00:13,250 --> 00:00:17,667
<b>Warning:</b> Reaching the air compressor base bolts is difficult.

4
00:00:17,667 --> 00:00:21,958
Exercise caution when removing the air compressor base bolts.

5
00:00:21,958 --> 00:00:27,583
Failure to do so may result in sprains, strains, or personal injury.

6
00:00:27,583 --> 00:00:36,292
<b>Note:</b> It is possible to remove the air compressor base bolts if the access door below the manual handbrake wheel is removed.

7
00:00:36,292 --> 00:00:41,042
A long extension may be necessary to access base bolts.

8
00:00:41,042 --> 00:00:48,083
9. Remove the air compressor hold-down bolts at the four corners of the air compressor base.

9
00:00:48,083 --> 00:00:57,875
<b>Warning:</b> The air compressor weighs approximately 2550 lbs. (1157 kg).

10
00:00:57,875 --> 00:01:02,667
Ensure the lifting device, cables, and straps are adequate.

11
00:01:02,667 --> 00:01:06,750
Failure to do so may result in personal injury or death.

12
00:01:06,750 --> 00:01:14,250
10. Use a come-along to move the air compressor to the walkway along the Engineer’s side of the locomotive.

13
00:01:14,250 --> 00:01:19,542
Carefully lift the air compressor with a crane and set it on the shop floor.