﻿GET_GEVOMechL2_11_01_01_35 - ANIMATION Screen
1
00:00:00,000 --> 00:00:07,833
During compressor loading, the CMV is de-energized and opens, venting the air pressure supply to the unloader valves.

2
00:00:07,833 --> 00:00:14,000
The unloader valves then open, allowing the compressor intake valves to operate normally.

3
00:00:14,000 --> 00:00:34,000
When operating normally, air enters the compressor cylinders through the intake valves during the intake stroke, the intake valves then close, the compressor’s pistons compress the air, exhausting the high-pressure air into the receiver, the compressor exhaust valves close and the process is repeated.

4
00:00:34,000 --> 00:00:41,500
With the compressor drive motor running and the compressor building air pressure, the compressor is operating in a “loaded” condition.