﻿GET_GEVOMechL2_11_01_01_16 - ANIMATION Screen
1
00:00:00,000 --> 00:00:08,333
The Air Reservoir Pressure Sensor (ARPS) measures the pressure of the air that is at the output of the first main air reservoir.

2
00:00:08,333 --> 00:00:18,583
The locomotive control system uses this information to turn the air compressor motor on and off and to control when the compressor is to load or unload.

3
00:00:18,583 --> 00:00:22,542
The end result is to regulate the air pressure in the system.

4
00:00:22,542 --> 00:00:28,042
This information is also presented on the smart displays for operator use.

5
00:00:28,042 --> 00:00:34,625
The ARPS is located on the air compressor control panel, which is in the radiator cab.

6
00:00:34,625 --> 00:00:40,250
Access to the panel is from the Engineer's side of the locomotive near the air compressor.