﻿GET_GEVOMechL2_10_01_01_38 - STEP-BY-STEP Screen
1
00:00:00,000 --> 00:00:10,500
<b>Warning – Falling Hazard: </b>To prevent a falling hazard, comply with all Railroad safety procedures before proceeding to the top of the blower cab.

2
00:00:10,500 --> 00:00:14,875
Typical steps to install the alternator blower are as follows:

3
00:00:14,875 --> 00:00:27,458
1. Clean the old industrial-type putty strip from the alternator blower mounting surface in the blower cab, then apply a new strip to the mounting surface to ensure an airtight seal.

4
00:00:27,458 --> 00:00:34,292
2. Lift the alternator blower with a crane and clean the bottom mounting surface of the blower.

5
00:00:34,292 --> 00:00:44,625
3. Place the alternator blower into position in the blower cab ensuring that the dirty air exhauster inlet air flange engages the gasket on the cab duct.

6
00:00:44,625 --> 00:00:54,083
4. Install the alternator blower mounting hardware and torque to 200 lb.-ft. (271 Nm).

7
00:00:54,083 --> 00:01:02,750
5. Apply Mortite Sealant to the bottom of the connecting plate where the bolt holes are located and connect the grease fitting lines.

8
00:01:02,750 --> 00:01:09,833
6. With the grease fitting lines reconnected, fill the grease lines with the recommended grease.