﻿GET_GEVOMechL2_10_01_01_36 - ANIMATION Screen
1
00:00:00,000 --> 00:00:10,292
<b>Warning:</b> Disconnect the Multiple Unit (MU) jumper cables connecting the locomotive being serviced to any other equipment prior to performing any maintenance tasks.

2
00:00:10,292 --> 00:00:14,500
Hazardous voltages may be present between interconnected units.

3
00:00:14,500 --> 00:00:21,000
Failure to disconnect the MU jumper cables from the locomotive being serviced may result in injury or death.

4
00:00:21,000 --> 00:00:29,708
To prevent personal injury and potential equipment damage when performing maintenance on cooling air system components, ensure the engine cannot be started.

5
00:00:29,708 --> 00:00:34,583
Place the Locomotive Battery Switch (LBS) in the OFF position.

6
00:00:34,583 --> 00:00:43,667
Place the Fuel Pump Circuit Breaker (FCB) and the Local Control Circuit Breaker (LCCB) in the OFF position.

7
00:00:43,667 --> 00:00:48,750
Apply a warning tag to the Engine Control (EC) switch.